Spectroscopic (analresidueytical) approach to gunshot analysis for shooting distance estimation: a systematic review

Abstract

Background

The determination of the shooting distance using gunshot residue (GSR) analysis is crucial in the investigation and reconstruction of firearm-related crimes. However, the conventional chemographic method for GSR analysis is destructive and has limited sensitivity and selectivity. While the spectroscopic method has potential in GSR analysis for crime investigation, there is a current lack of consistency in the spectroscopic results obtained for shooting distance estimation via GSR analysis. Addressing such limitations will enhance the forensic capabilities of law enforcement and provide an added advantage to crime laboratories during an investigation. It will also reinforce the use of such spectroscopic data in a criminal investigation.

Main text

We obtained all peer-reviewed articles relevant to shooting distance estimation from searching Scopus, Web of Science, PubMed, and Google Scholar databases. We specifically searched the databases using the keywords “shooting distance,” “range of fire,” “gunshot residue,” “firearm discharge residue,” and “firearm-related crime” and obtained 3811 records. We further filtered these records using a combination of two basic keywords “gunshot residue” and “shooting distance estimations” yielding 108 papers. Following a careful evaluation of the titles, abstracts, and full texts, 40 original peer-reviewed articles on shooting distance estimation via GSR analysis were included in the study. The forgoing included additional sources (n = 5) we obtained from looking through the reference lists of the forensic articles we found.

Short conclusion

This paper discusses the current scope of research concerning the chemographic and spectroscopic analysis of GSR for shooting distance estimation. It also examines the challenges of these techniques and provides recommendations for future research.

Background

Firearm-related crimes (FRC) such as armed robbery, homicide, suicide, and mass shootings threaten global public security and safety (Hemenway and Miller 2000). An estimated 18,000 children and adolescents die yearly in the US via injuries resulting from accidental gun firing (Cunningham et al. 2018). The foregoing is a consequence of the ease of access due to lax regulations on firearm possession (Hemenway and Miller 2000) and the influx of improvised/makeshift, including 3D printed (Chase and Laporte 2018; Walther 2015) and illegal firearms. In Ghana, an estimated 1.1 million unregistered firearms are illegally in civilian possession and have been implicated in the recent surge in FRC (Bokpe 2016).

Analysis of gunshot residues (GSR) from discharged firearms is vital in ballistic reconstruction in instances of FRC (Chang et al. 2013a2013b; Saverio Romolo and Margot 2001). Notably, the shooting distance, time since firearm discharge, ammunition type, trajectory or spatial position of the discharged firearm relative to its environment and target, injury pattern reconstruction, and linking an individual to gun use (Chang et al. 2013a2013b; Saverio Romolo and Margot 2001) can be estimated via GSR analysis. Gunshot residue mainly comprises burnt, unburnt, and partially burnt propellant charge, smoke, a cloud of vapor, and metal particles from the ammunition, and even the firearm (Dalby et al. 2010; López-lópez and García-ruiz 2014; Muller et al. 2007; Saverio Romolo and Margot 2001; Turillazzi et al. 2013). In addition, dispersion and deposition of GSR on the targets may be impacted by the environmental conditions and/or physical activities of the shooter (Zuzanna Brozek-Mucha 2011; Jalanti et al. 1999).

Consequently, shooting distance may be estimated by a visual comparison of casework GSR pattern with that generated from test-firing using the same firearm and ammunition involved in the crime (Capannesi et al. 1993; Dalby et al. 2010; López-lópez and García-ruiz 2014; Muller et al. 2007). Visualizing the GSR pattern on the victim of a crime is conventionally based on labor-intensive and subjective chemographic techniques (presumptive color test) (López-lópez and García-ruiz 2014). Despite their continued use in casework (Martiny et al. 2008), such color tests are not only destructive but have limited sensitivity and selectivity. Furthermore, the lack of efficiency in pattern enhancement of GSR from lead-free ammunition or nontoxic ammunition (Berendes et al. 2006) precludes recognition of chemographic tests as robust.

Analytical techniques based on spectroscopy have found utility in GSR analysis with promising results (Barth et al. 2012; Zuzanna Brozek-Mucha 2014; Cecchetto et al. 2011; Leiva et al. 2019; Santos et al. 2007; Zeichner 2003; Zeichner and Glattstein 2002). Particularly, the coupling of scanning electron microscope with energy-dispersive X-ray spectroscopy (SEM-EDS) has emerged as the technique of choice (Zuzanna Brozek-Mucha 2014; French and Morgan 2015). The SEM-EDS allows for both elemental composition and morphological examination of the characteristic primer GSR, typically lead (Pb), barium (Ba), and antimony (Sb). Additionally, the technique is also spatially discriminating, non-destructive, and requires no sample preparation (Z. Brozek-Mucha 2000; Zuzanna Brozek-Mucha 20092014; Dalby et al. 2010; Saverio Romolo and Margot 2001).

The merits, notwithstanding, spectroscopic analysis of GSR for shooting distance estimation (SDE) remain inconsistent. For example, while Gagliano-candela, Colucci, and Napoli claimed that atomic absorption spectroscopy (AAS) could estimate shooting distances up to 100 cm from the target, Gradaščević et al. showed that AAS was only effective up to 10 cm. This review discusses the conventional and modern techniques of GSR analysis for SDE; it also identifies challenges and gap in existing methods and provide a perspective on future direction.

Main text

Literature collection

All peer-reviewed articles relevant to SDE were obtained from searching Scopus, Web of Science, PubMed, and Google Scholar databases. We specifically searched the databases using the keywords “shooting distance,” “range of fire,” “gunshot residue,” “firearm discharge residue,” and “firearm-related crime” and obtained 3811 records (Scopus, n = 10; Web of Science, n = 33; PubMed, n = 28; Google scholar, n = 3740). We further filtered these records using a combination of two basic keywords “gunshot residue” and “shooting distance estimation” yielding 108 papers. After screening the titles and abstracts, we only included full-text articles describing original research that focused on GSR analysis for SDE (n = 40) in this study. The foregoing included additional sources obtained from the reference list of one original article (n = 5). We excluded supplementary published works, reviews, conference abstracts, discussion papers, editorials, errata, short communications, correspondence, and news. The search strategy is shown in Fig. 1.

Fig. 1

Results

GSR analysis for SDE

The distance between the gun’s muzzle end and the target is termed shooting distance or range of fire or muzzle-to-target distance. In the investigation and reconstruction of the FRC, determining the shooting distance is critical. The GSR exits the firearm through the muzzle end (and other openings in the firearm), travels a little distance before settling on the victim, and surfaces close to the firing site (Gallidabino et al. 2016). As a result, the relevance of the distance traveled by these residues cannot be ignored, given its critical significance in the investigation and reconstruction of shooting incidents. The methods used for GSR analysis for SDE can be categorized as chemographic or spectroscopic.

Chemographic analysis of GSR for SDE

The chemographic methods (Table 1) for GSR analysis relies on a color formation following a chemical reaction between a specific reagent and the metal elements in the GSR sample (Ananth et al. 2014; Chang et al. 2013a2013b; Niewoehner 2015; Saverio Romolo and Margot 2001; Schwoeble and Exline 2000; Tugcu et al. 2006; Zeichner and Glattstein 2006; Niewoehner 2015; Dalby et al. 2010). Thus, the technique is suitable for detecting both inorganic (metallic) and organic elements in GSR particles.

Table 1 Chemographic method for GSR analysis

Reference

Test type

Compound detected

Reagent used

Description/color reaction

Ananth, Kalthom, and Me (Ananth et al. 2014)

Dermal nitrate/paraffin test

Nitrate

Diphenylamine dissolved in strong sulfuric acid

Picked up GSR on paraffin wax + reagent gives a blue color spot indicating the presence of nitrates

Chang, Jayaprakash, and Yew (Chang et al. 2013ab)

Spot test

Lead (Pb)

Sodium rhodizonate

GSR sample + reagent gives a pink coloration indicating the presence of lead.

Saverio Romolo and Margot (2001)

Walker test/Marshal and Tewari test

Nitrite

2-Naphthylamine sulfanilic acid and citric acid

GSR sample + reagent gives a pink coloration for the presence of nitrite

Ananth et al. (2014)

Modified Griess test

Nitrite

Griess reagenta

GSR sample + reagent gives a rose color for the presence of nitrite

Dalby et al. (2010)

Harrison and Gilroy’s test

Lead (Pb), barium (Ba), and antimony (Sb)

• Triphenyl methylarsonium iodide alcoholic solution
• Sodium rhodizonate
• Dilute hydrochloric acid

GSR sample + triphenyl methylarsonium iodide alcoholic solution gives orange ring color for the presence of Sb. Two drops of sodium rhodizonate are added to the center of the orange ring, color changes to red for Pb or Ba or both. A drop of dilute hydrochloric acid is added to the red spot, color changes to blue for Pb. No color change is indicative of Ba

Ananth et al. (2014)

Lunge testb

Nitrocellulose (NC)

Lunge reagent

GSR sample + reagent gives a red azo color for NC

Niewoehner (2015)

Zincon reagent testc

Zinc (Zn) and titanium (Ti)

Zincon reagent

GSR sample + reagent gives a blue-colored complex for Zn and Ti

6
  • aGriess reagent: 3% sulfanilamide N-(1-naphthyl) ethylene diamide dihydrochloride in 5% sulfuric acid
  • bDetect organic compounds (NC) in GSR
  • cApplied to Pb-free ammunition, e.g., Sintox ammunition

Although the chemographic method is still used in casework for presumptive identification of a sample as GSR, its application in SDE has been limited and problematic. For instance, Marty, Sigrist, and Wyler determined the shooting distance (differentiated between close range and far range shot) using the rhodizonate staining technique on skin samples. The use of skin samples in this scenario increases the likelihood of generating a false positive result since the sodium rhodizonate reagents also produce positive results with keratinous structures of hair follicles (Andreola et al. 2011). The above technique was improved further via a heated press for the transference of GSR particles on clothing items for SDE (Geusens et al. 2019). Furthermore, Vinokurov, Zelkowicz, Udi, and Zeichner proposed a technique based on the influence of contamination of a victim’s clothing by GSR for a range of fire estimation using the modified Griess test (MGT) method. The detection of nitrite using the MGT method follows the reaction of the GSR sample with potassium hydroxide solution plus the MGT reagent (Atwater et al. 2006). While the MGT is effective, a method that reveals the GSR pattern on an item without chemicals or reagents would be preferable. Not only would this save time on reagent preparation, but it will also alleviate contrast problems when the GSR is present on a multi-colored fabric or target (Bailey et al. 2004).

Spectroscopic analysis of GSR for SDE

The spectroscopic technique deals with the interaction between specific electromagnetic radiation and the GSR sample. This technique estimates the concentration and yields information about the elemental composition (for example, Pb, Ba, and Sb) of the GSR sample. Spectroscopic techniques employed for GSR analysis to estimate the shooting distance are presented in Table 2.

Table 2 Spectroscopic analysis of GSR for SDE

Reference

Firearm/ammunition used

Technique

Target

Findings

Capannesi et al. (1993)

Not stated

NAA

• White cotton cloth

• Quantified Sb concentration around a bullet entrance hole at a firing distance of 16.5 cm (first shot) and 26.7 cm (second shot)

Santos et al. (2007)

6.35 mm pistol

ICP-MS

• Cotton tissue

• Quantified Pb, Ba, and Sb at a firing distance of 20 cm to 80 cm from the target at a radial distance of 1.5 cm to 5.5 cm from the bullet entrance hole

Gagliano-candela et al. (2008)

Colt 38 special

AAS

• Whatman paper on polystyrene support

• Determined the concentration of Pb on a target at a firing distance of up to 100 cm

Mou et al. (2008)

Remington model 552 rifle (0.22 caliber)

AFM and FTIR/ATR

• Polyethylene and aluminum foil sheet

• Characterized GSR particles at a firing distance of 0.5 ft, 2 ft, 10 ft, and 20 ft
• AFM images revealed varying shapes of the GSR particle with size and density inversely proportional to shooting distance

Bresson and Franck (2009)

Glock 26 semi-automatic pistol

Ballistic experiment

• Concrete wall

• Estimated the shooting distance from the impacting velocity of a bullet

Cecchetto et al. (2011)

7.65 mm pistol

Micro-CT

• Human leg

• Firing distance up to 40 cm was estimated through GSR analysis in an intermediate gunshot wound

Barth et al. (2012)

Glock model 19 semi-automatic pistol with different ammunition (9 mm × 19 GECO FMJ, 9 mm × 19 Sintox FMJ, and 9 mm × 19 Sintox forensic FMJ)

m-XRF

• 100% cotton denim
• A mixture of knitted 50% polyester and 50% acrylic fiber
• 100% acetate satin

• Estimated the range of fire up to 80 cm from the target

Turillazzi et al. (2013)

9 × 21 mm and 7.65 mm caliber handgun

Laser confocal microscopy and ICP-AES

• Pig skin

• Obtained a greater concentration of the elemental trio (Pb, Ba, and Sb) in a close-range shot relative to mid and far-range shots for both firearms

Gradaščević et al. (2013)

Pistol Crvena zastava M70/7.65 × 17 mm; Pistol Crvena zastava M57/7.62 × 25 mm; 9 mm luger pistol/9 × 19 mm; automated rifle/7.62 × 39 mm

AAS

• Pig skin

• Estimated shooting distance in contact (5 cm) and near contact (10 cm) shot using GSR obtained from a bullet entrance hole

Hinrichs et al. (2016)

.38 special revolver/.38 cartridge

VP-SEM

• Cotton and polyester textiles

• Obtained the pattern of GSR distribution with low vacuum SEM images
• Estimated firing distance using the decay length of GSR distribution pattern

Zapata et al. (2018)

Glock G17 pistol and 9 × 19 mm semi-jacketed hollow point ammunition

Multi-spectral imaging

• Cloth (white cotton fabric)

• Estimated the shooting distance of up to 220 cm

Leiva et al. (2019)

Revolver Taurus caliber with .38 ammunition

XRD

• Cotton-polyester fabric

• Quantified GSR and estimated the shooting distance up to 300 cm

Pyl et al. (2019)

9 mm pistol; Rossi revolver 0.357 magnum

LIBS

• Cotton textiles

• Produced permanent chemical images of residues for the correct classification of shooting distances

One of the earliest studies on SDE evaluated the concentration and pattern of Sb deposited around a bullet entrance hole using neutron activation analysis (NAA) at a firing distance of 16.5 cm and 26.7 cm for a first and second shot, respectively (Capannesi et al. 1993). Neutron activation analysis (NAA) is an isotope-based technique that works by bombarding stable atomic nuclei with neutrons (from a nuclear reactor) and measuring the energy and half-life of the emitted radiation (radioactive gamma rays) following the decay process (Greenberg et al. 2011). During GSR analysis, the technique exclusively measures the presence of radioactive Sb (Sb121 → Sb122) and Ba (Ba132 → Ba133). It is particularly sensitive and capable of analyzing difficult to dissolve elements (such as inorganic GSR) without sample pretreatment. However, apart from the relatively slow sample throughput, the method does not apply to the analysis of Pb and requires a powerful neutron source like a nuclear reactor. These limitations notwithstanding, NAA has been used in GSR analysis for forensic investigations (Chohra et al. 2015). The inductively coupled plasma-mass spectroscopy (ICP-MS) platform allows the examiner to obtain a very low detection limit due to its high sensitivity and facilitates rapid multi-elemental analysis, giving both qualitative and quantitative outputs (Biegstraaten and Horváth 2007). Excepting the high cost and the occurrence of spectral and non-spectral interferences during sample analysis, ICP-MS has proven invaluable for GSR analysis. Santos et al. used ICP-MS to profile the simultaneous presence of GSR elemental trio (Pb, Ba, and Sb) at a firing distance of not more than 80 cm away from the target. This finding supports the work of Barth et al. whose study estimated the shooting distance from GSR using milli-X-ray fluorescence (m-XRF). Unlike the ICP-MS, m-XRF is non-destructive, does not consume samples under examination, and efficiently detects and visualizes particles from Pb-free or nontoxic ammunition (example, sintox ammunition). Leiva et al. also estimated the shooting distance (between 5 and 300 cm) using x-ray diffraction (XRD) analysis.

Turillazzi et al. employed confocal laser microscopy and inductively coupled plasma with atomic emission spectroscopy (ICP-AES) to estimate the shooting distance and reported obtaining a greater concentration of Pb, Ba, and Sb in a close-range shot relative to mid and far range shot. The elemental trio (Pb, Ba, and Sb) establishes the identity of a sample as GSR. Further, a combination of micro-computed tomography (micro-CT) and image analysis software was used to quantify GSR present in a mid-range gunshot wound for SDE (≤ 40 cm) (Cecchetto et al. 2011). Although little data was presented on the elemental trio (Pb, Ba, and Sb) unique to primer GSR, the authors used human skin samples, representing an ideal simulation of real-life crime scene scenarios. Whereas the micro-CT technique is non-destructive (Cnudde et al. 2008), it has an increased likelihood of providing false-positive results (Cecchetto et al. 2011). Additionally, a multi-spectral imaging technique was effectively used for estimating the shooting distance (from 10 to 220 cm) following GSR analysis (Zapata et al. 2018). This technique has the added advantage of automatically examining GSR patterns through quantitative approaches.

Atomic absorption spectroscopy (AAS) works by measuring the amount of electromagnetic radiation (ultraviolet-visible radiation) absorbed by free atoms in a gaseous state (Yeung et al. 2017). A study by Gagliano-candela, Colucci, and Napoli concerning SDE extrapolated the firing distance (up to 100 cm) by analyzing the concentration of only Pb on a target using AAS. This result is consistent with the work of Gradaščević et al. (2013). Mou, Lakadwar, and Rabalais employed atomic force microscopy (AFM) and Fourier transform infrared attenuated total reflectance (FTIR/ATR) for SDE. Although the firing distance was estimated at 0.5 ft (15.24 cm), 2 ft (60.96 cm), 10 ft (304.8 cm), and 20 ft (609.6 cm) away from the target, the authors argued that characterization of the specific element in the GSR sample was not successful with FTIR/ATR. The FTIR/ATR technique is very sensitive, considering its ability to quantify GSR particles at a range up to 20 ft (609.6 cm) from the target. The FTIR/ATR can also produce a profile unique to the ammunition type, making it a valuable tool for differentiating ammunitions based on the GSR particles (Mou et al. 2008).

The impact velocity of a full metal jacketed (FMJ) 9 mm Parabellum bullet was determined through a series of shooting experiments by comparing a questioned bullet to a set of test-fired bullets striking a wall (Bresson and Franck 2009). The firing distance was subsequently estimated from the impact velocity after evaluating the bullet’s behavior (Bresson and Franck 2009). A variable pressure scanning electron microscope (VP-SEM) with characteristic high-resolution imaging and depth of field was introduced by Hinrichs et al. for SDE. This was achieved by establishing an exponential decay of the GSR distribution pattern on a target as a function of the radial distance of the particles from the bullet entry hole (Hinrichs et al. 2016). Pyl et al. showed that laser-induced breakdown spectroscopy (LIBS) is suitable for SDE. The LIBS performs better than the conventional chemographic technique in sensitivity, selectivity, reproducibility, accuracy, and multi-elemental detection capabilities (Pyl et al. 2019).

Limitations and future directions

Current research on GSR analysis for SDE has focused on collecting samples after test shots/firing in a controlled, indoor firing range. Whereas the findings from such studies are useful as proof of concept, it lacks practical applications in forensic casework scenarios where shootings may occur in an outdoor space exposed to natural environmental conditions. Therefore, extensive research is needed to study and understand the influence of environmental factors such as wind, temperature, rain, and humidity on the persistence and collection of GSR from a target. Further, the firearms and ammunition, range of fire, and spectroscopic technique employed varied from one study to another. Although such an approach is laudable, it has limited reproducibility for SDE. Hence, ensuring consistency and reliability in the spectroscopic results acquired for SDE will reinforce the use of such spectroscopic data in a criminal investigation. Also, extensive research and collaboration among practitioners are required to address the current lack of consensus on validated protocols, quality standards, and guidelines for interpreting spectroscopic results following GSR analysis for SDE.

Conclusions

The determination of shooting distance is a critical problem in firearm-related incidents where GSR is the only available evidence of probative value. Establishing the muzzle-to-victim distance through GSR analysis may contribute to linking a suspect to a shooting scene. However, the application of spectroscopy for SDE via GSR analysis in casework is limited due to the inconsistency in methods and lack of standardization and guidelines for interpreting results. In this paper, we have discussed the current scope of research concerning the chemographic and spectroscopic analysis of GSR for SDE, highlighted some limitations, and suggested further research directions to address them. Addressing such limitations will enhance the forensic capabilities of law enforcement and provide an added advantage to crime laboratories during an investigation.

Abbreviations

FRC: Firearm-related crime

GSR: Gunshot residue

SDE: Shooting distance estimation

AAS: Atomic absorption spectroscopy

SEM-EDS: Scanning electron microscope with energy-dispersive X-ray spectroscopy

ICP-MS: Inductively coupled plasma with mass spectroscopy

ICP-AES: Inductively coupled plasma with atomic emission spectroscopy

NAA: Neutron activation analysis

m-XRF: Milli X-ray fluorescence

XRD: X-ray diffraction

AFM: Atomic force microscopy

FTIR/ATR: Fourier transform infrared attenuated total reflectance

FMJ: Full metal jacketed

VP-SEM: Variable pressure scanning electron microscope

LIBS: Laser-induced breakdown spectroscopy

MGT: Modified Griess test

NC: Nitrocellulose

Pb: Lead

Ba: Barium

Sb: Antimony

Zn: Zinc

Ti: Titanium

References

  • Ananth V, Kalthom U, Me S (2014) Detection of organic gunshot residues for the estimation of firing distance 
  • Andreola S, Gentile G, Battistini A, Cattaneo C, Zoja R (2011) Forensic applications of sodium rhodizonate and hydrochloric acid: a new histological technique for detection of gunshot residues. J Forensic Sci 56(3):771–774. https://doi.org/10.1111/j.1556-4029.2010.01689.x 
  • Atwater CS, Durina ME, Durina JP, Blackledge RD (2006) Visualization of gunshot residue patterns on dark clothing. J Forensic Sci 51(5):1091–1095. https://doi.org/10.1111/j.1556-4029.2006.00226.x 
  • Bailey JA, Casanova RS, Bufkin K (2004) A comparison between the modified griess test and use of sodium hypochlorite for enhancement of gun shot residue patterns on fabric 1. Am Acad Forensic Sci:38–40
  • Barth M, Niewo L, Latzel S, Neimke D (2012) Shooting distance determination by m-XRF — examples on spectra interpretation and range estimation. Forensic Sci Int 223:273–278. https://doi.org/10.1016/j.forsciint.2012.10.001
  • Berendes A, Neimke D, Schumacher R, Barth M (2006) A versatile technique for the investigation of gunshot residue patterns on fabrics and other surfaces: m-XRF. J Forensic Sci 51(5):1085–1090. https://doi.org/10.1111/j.1556-4029.2006.00225.x 
  • Biegstraaten J, Horváth R (2007) Chemometric classification of gunshot residues based on energy dispersive X-ray microanalysis and inductively coupled plasma analysis with mass-spectrometric detection. 62:1028–1036. https://doi.org/10.1016/j.sab.2007.04.005
  • Bokpe, S. J. (2016). 1,300 Guns burnt but 1.1 million firearms in wrong hands-Small Arms Commission. Retrieved from https://www.graphic.com.gh/news/general-news/1-%0A300-guns-burnt-but-1-1-million-firearms-in-wronghands-%0Asmall-arms-commission.html Assessed May 31, 2021 
  • Bresson F, Franck O (2009) Estimating the shooting distance of a 9-mm Parabellum bullet via ballistic experiment. Forensic Sci Int 192:18–21. https://doi.org/10.1016/j.forsciint.2009.07.018 
  • Brozek-Mucha Z (2000) SEM-EDX study of inorganic gunshot residues from Makarov 9 mm ammunition. Z Zagadnien Nauk Sadowych 41:62–86 
  • Brozek-Mucha Z (2009) Distribution and properties of gunshot residue originating from a Luger 9 mm ammunition in the vicinity of the shooting gun. Forensic Sci Int 183(1–3):33–44. https://doi.org/10.1016/j.forsciint.2008.10.010 
  • Brozek-Mucha Z (2011) Chemical and morphological study of gunshot residue persisting on the shooter by means of scanning electron microscopy and energy dispersive X-ray spectrometry. Microscopy Microanalysis 17(6):972–982. https://doi.org/10.1017/S1431927611012141 
  • Brozek-Mucha Z (2014) On the prevalence of gunshot residue in selected populations – an empirical study performed with SEM-EDX analysis. Forensic Sci Int 237:46–52. https://doi.org/10.1016/j.forsciint.2014.01.020 
  • Capannesi G, Ciavola C, Sedda AF (1993) Determination of firing distance and firing angle by neutron activation analysis in a case involving gunshot wounds. Forensic Sci Int 61(2–3):75–84. https://doi.org/10.1016/0379-0738(93)90216-W 
  • Cecchetto G, Giraudo C, Amagliani A, Viel G, Fais P, Cavarzeran F et al (2011) Estimation of the firing distance through micro-CT analysis of gunshot wounds. Int J Legal Med 125(2):245–251. https://doi.org/10.1007/s00414-010-0533-6 
  • Chang KH, Jayaprakash PT, Yew CH (2013a) Gunshot residue analysis and its evidential values: a review, p 0618. https://doi.org/10.1080/00450618.2012.691546 
  • Chang KH, Jayaprakash PT, Yew CH, Abdullah AFL (2013b) Gunshot residue analysis and its evidential values: a review. Austr J Forensic Sci 45(1):3–23. https://doi.org/10.1080/00450618.2012.691546 
  • Chase RJ, Laporte G (2018) The next generation of crime tools and challenges: 3D printing. NIJ J 279:49–57 
  • Chohra M, Beladel B, Baba Ahmed L, Mouzai M, Akretche D, Zeghdaoui A et al (2015) Study of gunshot residue by NAA and ESEM/EDX using several kinds of weapon and ammunition. J Radiat Res Applied Sci 8(3):404–410. https://doi.org/10.1016/j.jrras.2015.02.012 
  • Cnudde V, Masschaele B, De Cock H, Olstad VL, J. P. (2008) Virtual histology by means of high-resolution X-ray CT. J Microsc 232(May):476–485 
  • Cunningham RM, Walton MA, Carter PM (2018) The major causes of death in children and adolescents in the United States. N Engl J Med 379(25):2468–2475. https://doi.org/10.1056/nejmsr1804754 
  • Dalby O, Butler D, Birkett JW (2010) Analysis of gunshot residue and associated materials – a review. J Forensic Sci 55(4):924–943. https://doi.org/10.1111/j.1556-4029.2010.01370.x 
  • French J, Morgan R (2015) An experimental investigation of the indirect transfer and deposition of gunshot residue: Further studies carried out with SEM-EDX analysis. Forensic Sci Int 247:14–17. https://doi.org/10.1016/j.forsciint.2014.10.023
  • Gagliano-candela R, Colucci AP, Napoli S (2008) Determination of firing distance . lead analysis on the target by atomic absorption spectroscopy (AAS). J Forensic Sci 53(2):321–324. https://doi.org/10.1111/j.1556-4029.2008.00668.x
  • Gallidabino M, Romolo FS, Weyermann C (2016) Time since discharge of 9 mm cartridges by headspace analysis , part 2 : ageing study and estimation of the time since discharge using. Forensic Sci Int. https://doi.org/10.1016/j.forsciint.2016.12.027
  • Geusens N, Nys B, Sebastien C (2019) Implementation and optimization of the sodium-rhodizonate method for chemographic shooting distance estimation. J Forensic Sci 5:5–8. https://doi.org/10.1111/1556-4029.13984
  • Gradaščević A, Resić E, Sarajlić N, Franjić B, Salkić A, Džuzdanović-Pašalić A (2013) Is it possible to determine firearm calibre and shooting range from the examination of gunshot residue in close range gunshot wounds? An experimental study. J Health Sci 3(3):232–237. https://doi.org/10.17532/jhsci.2013.113 
  • Greenberg RR, Bode P, De Nadai Fernandes EA (2011) Neutron activation analysis: a primary method of measurement. Spectrochim Acta Part B Atomic Spectrosc 66(3–4):193–241. https://doi.org/10.1016/j.sab.2010.12.011 
  • Hemenway D, Miller M (2000) Firearm availability and homicide rates across 26 high- income countries. J Trauma 49(2):985–988 
  • Hinrichs R, Frank PO, Vasconcellos MAZ (2016) Short range shooting distance estimation using variable pressure SEM images of the surroundings of bullet holes in textiles. Forensic Science Int. https://doi.org/10.1016/j.forsciint.2016.12.033
  • Jalanti T, Henchoz P, Gallusser A, Bonfanti MS (1999) First Meeting of the European Academy of Forensic Sciences, Lausanne, Switzerland, 1997: The persistence of gunshot residue on shooters’ hands. Sci Justice J Forensic Sci Soc 39(1):48–52. https://doi.org/10.1016/s1355-0306(99)72014-9 
  • Leiva K, Ortega-ojeda FE, García-ruíz C (2019) Chemometrics and Intelligent Laboratory Systems Shooting distance estimation based on gunshot residues analyzed by XRD and multivariate analysis. 193(August). https://doi.org/10.1016/j.chemolab.2019.103831
  • López-López M, Alvarez-Llamas C, Pisonero J, García-Ruiz C, Bordel N (2017) An exploratory study of the potential of LIBS for visualizing gunshot residue patterns. Forensic Sci Int 273:124–131. https://doi.org/10.1016/j.forsciint.2017.02.012 
  • López-lópez M, García-ruiz C (2014) Recent non-chemical approaches to estimate the shooting distance. Forensic Sci Int. https://doi.org/10.1016/j.forsciint.2014.03.023
  • Martiny A, Campos APC, Sader MS, Pinto MAL (2008) SEM/EDS analysis and characterization of gunshot residues from Brazilian lead-free ammunition. Forensic Sci Int 177(1). https://doi.org/10.1016/j.forsciint.2007.07.005
  • Mou Y, Lakadwar J, Rabalais JW (2008) Evaluation of shooting distance by AFM and FTIR/ATR analysis of GSR. J Forensic Sci 53(6):1381–1386. https://doi.org/10.1111/j.1556-4029.2008.00854.x 
  • Muller D, Levy A, Vinokurov A, Ravreby M, Shelef R, Wolf E et al (2007) A novel method for the analysis of discharged smokeless powder residues. J Forensic Sci 52(1):75–78. https://doi.org/10.1111/j.1556-4029.2006.00309.x 
  • Niewoehner, L. H. (2015). Improved methods for the collection of gunshot residues (GSR) and for chemographic testing of lead-free Sintox TM ammunition improved methods for the collection of gunshot residues (GSR) and for chemographic testing of lead-free Sintox TM Ammunition. (April 2003).
  • Pyl CV, Ovide O, Ho M, Yuksel B, Trejos T (2019) Spectrochimica Acta Part B Spectrochemical mapping using laser induced breakdown spectroscopy as a more objective approach to shooting distance determination. Spectrochimica Acta Part B 152(November 2018):93–101. https://doi.org/10.1016/j.sab.2018.12.010 
  • Santos A, Magalhães T, Vieira DN, Almeida AA, Sousa AV (2007) Firing distance estimation through the analysis of the gunshot residue deposit pattern around the bullet entrance hole by inductively coupled plasma-mass spectrometry: an experimental study. Am J Forensic Med Pathol 28(1):24–30. https://doi.org/10.1097/01.paf.0000233631.40170.d4 
  • Saverio Romolo F, Margot P (2001) Identification of gunshot residue: a critical review. Forensic Sci Int 119(2):195–211. https://doi.org/10.1016/S0379-0738(00)00428-X 
  • Schwoeble A, Exline DL (2000) Current methods in gunshot residue analysis. CRC Press. https://doi.org/10.1017/CBO9781107415324.004
  • Tugcu H, Yorulmaz C, Karslioglu Y, Uner HB, Koc S, Ozdemir C et al (2006) Image analysis as an adjunct to sodium rhodizonate test in the evaluation of gunshot residues: an experimental study. Am J Forensic Med Pathol 27(4):296–299. https://doi.org/10.1097/01.paf.0000248739.79253.25 
  • Turillazzi E, Di Peri GP, Nieddu A, Bello S, Monaci F, Neri M et al (2013) Analytical and quantitative concentration of gunshot residues (Pb, Sb, Ba) to estimate entrance hole and shooting-distance using confocal laser microscopy and inductively coupled plasma atomic emission spectrometer analysis: An experimental study. Forensic Sci Int 231(1–3):142–149. https://doi.org/10.1016/j.forsciint.2013.04.006 
  • Walther G (2015) Printing insecurity? The security implications of 3D-printing of weapons. Sci Eng Ethics 21(6):1435–1445. https://doi.org/10.1007/s11948-014-9617-x 
  • Yeung V, Miller DD, Rutzke MA (2017) Atomic absorption spectroscopy, atomic emission spectroscopy, and inductively coupled plasma-mass spectrometry:129–150. https://doi.org/10.1007/978-3-319-45776-5_9
  • Zapata F, López-lópez M, Manuel J, García-ruiz C (2018) Multi-spectral imaging for the estimation of shooting distances. Forensic Sci Int 282:80–85. https://doi.org/10.1016/j.forsciint.2017.11.025
  • Zeichner A (2003) Recent developments in methods of chemical analysis in investigations of firearm-related events. Analytic Bioanalytic Chem 376(8):1178–1191. https://doi.org/10.1007/s00216-003-1994-y
  • Zeichner A, Glattstein B (2002) Recent developments in the methods of estimating shooting distance. ScientificWorldJournal 2:573–585. https://doi.org/10.1100/tsw.2002.140 
  • Zeichner A, Glattstein B (2006) Improved reagents for firing distance determination, pp 37–41. https://doi.org/10.1080/07370658608011341

Author information

Affiliations

  • Department of Forensic Sciences, University of Cape Coast, Cape Coast, Ghana

Maxwell Abedi, Dan O. M. Bonsu, Isaac K. Badu & Richmond Afoakwah

  • School of Biological Sciences, The University of Adelaide, Adelaide, South Australia, Australia

Dan O. M. Bonsu

  • School of Forensic Sciences, National Forensic Sciences University, Gandhinagar, India

Pooja Ahuja

Contributions

MA and DOMB contributed to the conception of the article, research for the article, drafting of manuscript, review, and editing of the manuscript; IKB, RA, and PA contributed to the drafting of paper, review, and editing of the paper. All authors read and approved the final manuscript.

Corresponding authors

Correspondence to Maxwell Abedi or Dan O. M. Bonsu.

Join Maxwell Abedi on LinkedIn

Cite this Article:

Abedi, M., Bonsu, D.O.M., Badu, I.K. et al. Spectroscopic (analytical) approach to gunshot residue analysis for shooting distance estimation: a systematic review. Egypt J Forensic Sci 11, 34 (2021). https://doi.org/10.1186/s41935-021-00253-3

Forensic Ballistics Experts QnA
1. What is ballistics? Answer: The word "ballistics" …
Human Forensic DNA Analysis Process Map
SUMMARY Forensic DNA analysis is based on the …
Acquiring Windows Operating System Credentials Through Bitlocker: A Digital Forensic Approach
ABSTRACT of Acquiring Windows Operating System Credentials Through …
What is the role of Ground-penetrating radar systems in Geo forensics?
The geophysical locating technique known as ground penetrating …
error: Content is protected !!

Discover more from Forensic's blog

Subscribe now to keep reading and get access to the full archive.

Continue reading